CVA-24T To Ortega Valve 2 in. Adapter Kit made by Pentair OVA2
APPLICATION:
Used to adapt Compool CVA-24T Valve Actuator to 2 Ortega 3-port valve.
KIT INCLUDES:
- Adapter Plate
- Cover O-ring Seal
- Cover O-ring Seals (3ea.)
- Shaft Coupling
- Shaft Coupling Mounting Screws (2 ea.)
- Valve Handle
- Valve Knob
INSTALLATION:
- Remove handle, cover, stop screw and o-ring seals from OrtegaValve. Save cover screws.
- Insert new O-ring Seals into bottom of Adapter Plate. LubricateSeals with Compool Silicone Grease. In retrofit applications, itis advisable to remove the valve diverter and lubricate diverterseal at this time.
- Valves should be inspected and serviced at lease once a year. The valve diverter should be well lubricated, the O-ring seals should be intact, and the diverter should fit snugly and rotate smoothly
- Mount Adapter plate to valve, using the existing cover screws.
- Attach Shaft Coupling to valve shaft. ensure that pointer isoriented in the direction of theopenvalve port. SecureCoupling with Mounting Screws. Tighten Screws completely.
- Attach Valve Handle to Valve Actuator, and secure with ValveKnob.
- Connect cable between Valve Actuator, and Power Center.Line-up and attach Valve Actuator to Shaft Coupling in thisposition, reverse the cable plug on the side of the ValveActuator so that the Actuator rotates to the correct position.
- Secure to Adapter plate with Valve Actuator Mounting Screws.
Pentair Adapter Kit, Size: 2 Inch, Includes: Adapter Plate, Cover O-Ring Seal, Shaft Coupling, Shaft Coupling Mounting Screws, Valve Handle, Valve Knob, For Use With: CVA-24T to Ortega(R) Valve, Actuator